Vcenter 6.0 - VCDB VC FATAL: the database system is starting up

$
0
0

Dear All

 

I found that the inventory service is not starting up and look up the log in C:\ProgramData\VMware\vCenterServer\logs\vpostgres

The DB status is always in "starting up" with FATAL. Does anyone know how to fix it? Please find attached logs.

 

2019-10-08 14:28:33.079 HKT 5d9c2c91.a0c 0 VCDB vc FATAL:  the database system is starting up

2019-10-08 14:29:48.425 HKT 5d9c0db9.2104 0   LOG:  received fast shutdown request

2019-10-08 15:09:16.702 HKT 5d9c361c.2790 0   LOG:  database system was interrupted while in recovery at 2019-10-08 12:16:58 HKT

2019-10-08 15:09:16.702 HKT 5d9c361c.2790 0   HINT:  This probably means that some data is corrupted and you will have to use the last backup for recovery.

2019-10-08 15:10:02.234 HKT 5d9c361c.2790 0   LOG:  database system was not properly shut down; automatic recovery in progress

2019-10-08 15:10:02.241 HKT 5d9c361c.2790 0   LOG:  redo starts at 41/83FE29B8

2019-10-08 15:10:05.853 HKT 5d9c361c.2790 0   LOG:  redo done at 41/85FFF6D8

2019-10-08 15:10:05.853 HKT 5d9c361c.2790 0   LOG:  last completed transaction was at log time 2019-10-06 05:45:05.252+08

2019-10-08 15:20:42.924 HKT 5d9c361c.2370 0   LOG:  received fast shutdown request

2019-10-08 15:25:05.862 HKT 5d9c39d1.1870 0   LOG:  database system was interrupted while in recovery at 2019-10-08 15:10:02 HKT

2019-10-08 15:25:05.862 HKT 5d9c39d1.1870 0   HINT:  This probably means that some data is corrupted and you will have to use the last backup for recovery.

2019-10-08 15:25:09.850 HKT 5d9c39d1.1870 0   LOG:  database system was not properly shut down; automatic recovery in progress

2019-10-08 15:25:09.874 HKT 5d9c39d1.1870 0   LOG:  redo starts at 41/83FE29B8

2019-10-08 15:25:14.612 HKT 5d9c39d1.1870 0   LOG:  redo done at 41/85FFF6D8

2019-10-08 15:25:14.618 HKT 5d9c39d1.1870 0   LOG:  last completed transaction was at log time 2019-10-06 05:45:05.252+08

2019-10-08 15:25:25.159 HKT 5d9c39e5.1ad4 0 VCDB vc FATAL:  the database system is starting up

2019-10-08 15:36:04.705 HKT 5d9c3c64.8b8 0 VCDB vc FATAL:  the database system is starting up

2019-10-08 15:36:59.679 HKT 5d9c3c9b.1d8c 0 VCDB vc FATAL:  the database system is starting up

2019-10-08 15:38:25.192 HKT 5d9c3cf1.270 0 VCDB vc FATAL:  the database system is starting up

2019-10-08 15:42:38.272 HKT 5d9c3dee.1648 0 VCDB vc FATAL:  the database system is starting up

2019-10-08 15:43:14.428 HKT 5d9c3e12.1f4c 0 VCDB vc FATAL:  the database system is starting up


Why is there still trafic through the VMware Network Adapter when it's shut off?

$
0
0

Why is there still trafic through the VMware Network Adapter when it's shut off?

I see trafic through the adapter using Wireshark, why is that? And can i stop the trafic until i turn the vmware on?

Fusion 11.1.1 Printers not on tool bar after windows 10 upgrade

$
0
0

Did latest Windows 10 upgrade this AM and saw that my printers were no longer visible on task bar at top of screen on Fusion 11.1.1?

 

I have tried to re-install VMware tools thru menu as well as manually per instructions.  No effect.  Can not see printers or any USB devices (all printers are connected via USB).

 

Manually re-installed virtual printer as well thru instructions.  No help.

 

Printers and queue(s) are visible and working on Windows 10 side. Just not outputting print jobs. 

 

Now I can only print from Mac side on MAC OS Mojave v 10.14.6?

Unable to edit vm, throws disk size error even though disk hasn't been changed

$
0
0

Hi Guys,

 

We have several clients running into this issue with the latest one being on ver 6.0u2. What happens is that I'll try to edit a VM, when I click OK even without changing anything, it throws the error "The disk capacity specified is greater than the amount available in the datastore". The datastore of the current one I'm working on is 500GB in size and the total amount committed + used was less than 400GB. It almost seems like it's not calculating the used space and only looking at the free space available.

 

I have been unable to find a solution for this. Does anyone have any hints on how I should go about resolving this issue?

 

Thanks,

Andy

No network in CentOS 8 virtual machine

$
0
0

Hi, I have installed manually VmWare tools, now it running, also I have installed NetworkManager. I see my CentOS virtual machine MAC-address in virtual switch. But I still have no network in CentOS virtual machine. Why?

Sorry for screen, but I have no network and have no SSH in that VM.

Opening files from Windows WM on Mac

$
0
0

Hello,

 

I'm able to open files that are stored on my Desktop and Documents from Windows to my macOS application, but not files stored at other Windows locations. VMware mention sharing options, but I have absolutely no idea about how to share folders to my macOS, and I can't find any documentation on this when searching.

 

-JM

Setting TimeZone on a VM

$
0
0

I am trying to set a vdi's timezone.  How do i do that with DEM, use the ADMX settings?  The GPO i think i need to set is below.

 

Computer\HKEY_LOCAL_MACHINE\SYSTEM\ControlSet001\Control\TimeZoneInformation

  

I believe I want to set the TimeZoneKeyName, StandardName and DaylightName.  I assume this would be in the Computer ADMX-based settings but couldn't find it. I also checked in the User ADMX-based settings and didn't find it.

 

I want to set the computer TimeZone to always be HST.

 

I h

 

vRA 8: Sorting of properties for dynamic list in custom form

$
0
0

Hi all,

 

I want to provide for users list of sorting values in Custom Form using vRO Action (for example: tier-1, tier-2), but sort order in Properties object is not alphabetic. Is there some way to sort elements in Properties object?

 

Examples:

 

step1.JPG

 

But

step2.JPG


vRA 8.1 - How to use project custom properties in custom form with vRO external action ?

$
0
0

Hi all,

 

I'm new to vRA 8.1, and I'm pretty happy of lots of things improved !

 

But while trying to reproduce my Blueprint and its Custom Form from vRA 7.5 to vRA 8.1, I'm struggling with something that was not difficult previously.

I need to fill a dropdown list with a REST API call from an external vRO action.

The REST Host was successfully added in vRO (this is one of the inputs for this action and it's working fine).

I need two others inputs to filter the content of the list that I'll display on form:

- environment of blueprint (easy as I added it in the inputs section of the Blueprint, I just select it in Fields)

- the group that is granted to acces only some items in the original list and here is my problem...

 

This group should be different for each project as projects replace Business Groups.

So I set a custom property in my project with one of the possible values, but I'm struggling retrieving this property in the custom form designer or inside my vRO external action.

 

In vRA 7.5, I was passing the Business Group name to my vRO external action and then used the action System.getModule("com.vmware.library.vcaccafe.subtenant").getCustomPropertyNames(subtenant) to retrieve all properties of the BG and then retrieve my property value.

But now it's just becoming a nightmare on the vRO side...

  • No vRA plugin...
  • No action containing the word 'project'
  • API explorer not organized to list vRA capabilities

 

I found this action that I could use: com.vmware.library.customProperties.getCustomProperty but its input is object type and I don't see any trace of method somewhere to get my project in the API so how can achieve that ????!!

 

I was curious enough to find something in API and did a test using Server.getObjectsWithCustomPropertyKey(myCustomProperty) and it return an empty object

 

Please help me I'm getting very confused

 

 

Cheers,

 

Tim

 

 

Workspace one UEM Integration error

$
0
0

I am trying to integrate  UEM to  IDM via the System - Integration - Workspace

Created API cert

 

VMware SaaS Environment Details
Group ID:
td_ashicd7a1SP
Tenant URL:

Does anyone know what this error is and how to resolve it ?

 

I followed the tech guides correctly,  but this is the error i get .

 

  • Save Failed
  • Your Workspace ONE Access tenant has already been configured with another Workspace ONE UEM tenant or Organization Group. Go to Identity & Access Management > Setup > AirWatch to manually update your tenant with Workspace ONE UEM details. See page 14 of the Deployment Guide for details on how to configure.

 

 

 

 

 

 

 

 

 

 

 

 

 

How do i resolve this error?

I have seen this article but this for UEM 2003 and i am on the latest SAAS offering from VMWare

https://kb.vmware.com/s/article/78470

ECDSA based PKI

$
0
0

Hello-

 

We are looking at standing up a ECDSA (ECC) based PKI managed via Digicert and configuring AW UEM to act as a RA with that.  The Offline Root CA, ICA, and device certs will all be ECDSA based.  Has anyone done this?  References I see in the documentation seem to mention predominately RSA based 2048bit certs.

 

Appreciate any info or feedback that folks have.

 

Thanks,

 

Dave

vRA 8.1 - Select AD Bind Location (Override AD Integration OU)

$
0
0

I am looking for a way to allow a user to choose their AD bind location at request time in vRA 8.1. We were able to achieve this in 7.6 by overriding a custom property and away it went, so now I'm trying to achieve that same behavior within 8.x. I've already got AD integration configured and I can see vRA creating/deleting computer objects in the configured OU. Now I'm looking for a way to override the location.

 

I understand it may be possible if we bypass the use of AD integration in favor of event subscriptions and custom workflows. I've also read a few users here complain that AD integration has a few bugs in it where objects are not getting created. Ideally I'd first like to give AD integration a shot before looking at the subscription method.

 

Any thoughts are welcomed. Thanks for reading.

Get cluster and ID per data store

$
0
0

Hi,

I am trying to write a script that lists the data store name, the cluster it belong to and the ID in a format that looks about like this:

CLUSTERNAME     DATASTORE_NAME    naa.xyz123xxxxxxxxxxxxxxxxxxxxxxxxxxxxx

 

I poked around and found 2 scripts that do each of the parts, but I cannot figure out how to merge them, so so speak.

 

Data store and cluster name:

 

Get-Cluster -PipelineVariable cluster |

Get-Datastore |

select @{N='Cluster';E={$cluster.Name}}Name, Type, FilesystemVersion, State, Accessible | Out-GridView

 

Get data store name and ID:

 

Get-Datastore | where{$_.Type -eq 'VMFS'} |

Select Name,

    @{N='LUN';E={$_.ExtensionData.Info.Vmfs.Extent.DiskName -join ' | '}}

 

Now, can anyone explain how I merge these, getting the

 

@{N='LUN';E={$_.ExtensionData.Info.Vmfs.Extent.DiskName -join ' | '}}

 

to be part of the first script?

VMware ESXI Genshin Impact with Windows 10 OS (Hide virtualization from guest OS)

$
0
0

As the title says I'm trying to get Genshin Impact to run on a Windows 10 VM on VMware ESXI version 6.7. It's taken quite a long time but so far I've managed to set up a VM with a NVidia Geforce 2070 passed through to the vm. I added the line ```hypervisor.cpuid.v0 = "FALSE"``` to the vmx file and hooked up a dummy monitor to the GPU to allow Parsec to remotely connect to it. I've tested several games such as Minecraft Java Edition, Subnautica Below Zero(running on Steam), and Rocket League(running on the Epic Games Launcher) and they all work fine.

After looking for a while on line I've come up with several more lines to add to the vmx file that seem to fix a similar problem with a game called Sword of the New World. However, when I run Genshin Impact it still comes up with a gui saying "Sorry, this application cannot run under a Virtual Machine."

I have also found that if running the vm off of KVM with Linux(which I am not willing to do after spending three weeks teaching myself how to setup ESXI with a VM that can be remotely accessed with parsec) apparently upon adding

```

<cpu mode='host-passthrough' check='none'>

...

    <feature policy='disable' name='hypervisor'/>

</cpu>

```

to the xml file, Genshin Impact works just fine.

I feel that there must be an equivalent string I can add to the vmx file for VMware ESXI that would do the same thing but after quite a bit of research I haven't found anything that works. I did come across a lot of users and forums that explain that it will not work on Shadow or virtual box, but nothing about VMware. Does anybody know an equivalent command for ESXI?

 

.vmx file:

```

.encoding = "UTF-8"

config.version = "8"

virtualHW.version = "14"

vmci0.present = "TRUE"

floppy0.present = "FALSE"

numvcpus = "6"

memSize = "11264"

bios.bootRetry.delay = "10"

powerType.suspend = "soft"

tools.upgrade.policy = "manual"

sched.cpu.units = "mhz"

sched.cpu.affinity = "all"

vm.createDate = "1602110300706076"

scsi0.virtualDev = "lsisas1068"

scsi0.present = "TRUE"

sata0.present = "TRUE"

usb_xhci.present = "TRUE"

scsi0:0.deviceType = "scsi-hardDisk"

scsi0:0.fileName = "Nix_1.vmdk"

sched.scsi0:0.shares = "normal"

sched.scsi0:0.throughputCap = "off"

scsi0:0.present = "TRUE"

ethernet0.virtualDev = "e1000e"

ethernet0.networkName = "VM Network"

ethernet0.addressType = "generated"

ethernet0.wakeOnPcktRcv = "FALSE"

ethernet0.present = "TRUE"

sata0:0.deviceType = "cdrom-image"

sata0:0.fileName = "/vmfs/volumes/5f7df0e5-3420089e-16a9-002655daae9a/os_images/Windows.iso"

sata0:0.present = "TRUE"

displayName = "Nix"

guestOS = "windows9-64"

toolScripts.afterPowerOn = "TRUE"

toolScripts.afterResume = "TRUE"

toolScripts.beforeSuspend = "TRUE"

toolScripts.beforePowerOff = "TRUE"

tools.syncTime = "FALSE"

uuid.bios = "56 4d e9 ca 46 e7 34 5c-b4 66 e3 ce a8 07 1c ac"

uuid.location = "56 4d e9 ca 46 e7 34 5c-b4 66 e3 ce a8 07 1c ac"

vc.uuid = "52 9a c9 a3 02 99 09 28-07 36 8d 25 db 2c be cf"

sched.cpu.min = "0"

sched.cpu.shares = "normal"

sched.mem.min = "11264"

sched.mem.minSize = "11264"

sched.mem.shares = "normal"

ethernet0.generatedAddress = "00:0c:29:07:1c:ac"

vmci0.id = "-1475928916"

cleanShutdown = "FALSE"

sata0:0.startConnected = "TRUE"

nvme0.present = "TRUE"

config.readOnly = "FALSE"

extendedConfigFile = "Nix_1.vmxf"

sound.autoDetect = "TRUE"

sound.virtualDev = "hdaudio"

sound.present = "TRUE"

sound.allowGuestConnectionControl = "TRUE"

sound.fileName = "-1"

svga.vramSize = "268435456"

mks.enable3d = "TRUE"

pciPassthru0.present = "TRUE"

pciPassthru1.present = "TRUE"

pciPassthru0.id = "00000:010:00.0"

pciPassthru0.deviceId = "0x1e84"

pciPassthru0.vendorId = "0x10de"

pciPassthru0.systemId = "5f74b25d-327c-6a86-6713-002655daae9a"

pciPassthru1.id = "00000:010:00.1"

pciPassthru1.deviceId = "0x10f8"

pciPassthru1.vendorId = "0x10de"

pciPassthru1.systemId = "5f74b25d-327c-6a86-6713-002655daae9a"

cpuid.coresPerSocket = "6"

svga.numDisplays = "2"

svga.autodetect = "FALSE"

tools.guest.desktop.autolock = "FALSE"

nvram = "Nix_1.nvram"

pciBridge0.present = "TRUE"

svga.present = "TRUE"

pciBridge4.present = "TRUE"

pciBridge4.virtualDev = "pcieRootPort"

pciBridge4.functions = "8"

pciBridge5.present = "TRUE"

pciBridge5.virtualDev = "pcieRootPort"

pciBridge5.functions = "8"

pciBridge6.present = "TRUE"

pciBridge6.virtualDev = "pcieRootPort"

pciBridge6.functions = "8"

pciBridge7.present = "TRUE"

pciBridge7.virtualDev = "pcieRootPort"

pciBridge7.functions = "8"

hpet0.present = "TRUE"

RemoteDisplay.maxConnections = "1"

sched.cpu.latencySensitivity = "medium"

disk.EnableUUID = "TRUE"

numa.autosize.cookie = "60001"

numa.autosize.vcpu.maxPerVirtualNode = "6"

sched.swap.derivedName = "/vmfs/volumes/5f7df0e5-3420089e-16a9-002655daae9a/Nix_1/Nix_1-0b2ace3b.vswp"

pciBridge0.pciSlotNumber = "17"

pciBridge4.pciSlotNumber = "21"

pciBridge5.pciSlotNumber = "22"

pciBridge6.pciSlotNumber = "23"

pciBridge7.pciSlotNumber = "24"

scsi0.pciSlotNumber = "160"

ethernet0.pciSlotNumber = "192"

usb_xhci.pciSlotNumber = "224"

vmci0.pciSlotNumber = "32"

sata0.pciSlotNumber = "33"

scsi0.sasWWID = "50 05 05 6a 46 e7 34 50"

ethernet0.generatedAddressOffset = "0"

vm.genid = "-1816076186780706416"

vm.genidX = "-8688614713756288280"

monitor.phys_bits_used = "43"

vmotion.checkpointFBSize = "4194304"

vmotion.checkpointSVGAPrimarySize = "268435456"

softPowerOff = "FALSE"

tools.remindInstall = "FALSE"

toolsInstallManager.lastInstallError = "0"

nvme0.pciSlotNumber = "256"

toolsInstallManager.updateCounter = "3"

sched.mem.pin = "TRUE"

sound.pciSlotNumber = "34"

svga.guestBackedPrimaryAware = "TRUE"

hypervisor.cpuid.v0 = "FALSE"

pciPassthru0.pciSlotNumber = "1184"

pciPassthru1.pciSlotNumber = "1216"

migrate.hostLog = "./Nix_1-0b2ace3b.hlog"

scsi0:0.redo = ""

monitor_control.virtual_rdtsc = "false"

monitor_control.restrict_backdoor = "true"

isolation.tools.getPtrLocation.disable = "true"

isolation.tools.setPtrLocation.disable = "true"

isolation.tools.setVersion.disable = "true"

isolation.tools.getVersion.disable = "true"

monitor_control.disable_directexec = "true"

usb_xhci:4.present = "TRUE"

usb_xhci:4.deviceType = "hid"

usb_xhci:4.port = "4"

usb_xhci:4.parent = "-1"

```

 

This is what I got for ```systeminfo``` in the vm windows command line:

```

Hyper-V Requirements:      VM Monitor Mode Extensions: No

                           Virtualization Enabled In Firmware: Yes

                           Second Level Address Translation: No

                           Data Execution Prevention Available: Yes

```

 

And yes the virtual machine name is Latin for snow. I themed them.

Also let me know if you need any more info. I'd be happy to comply.

VCSA install - Unable to save IP settings

$
0
0

Trying to install latest VCSA  7.0.1 trial in lab under VM Workstation but getting "Unable to save IP settings" during the set up phase no matter what I do.

 

VM is allocated 2 x Intel Core i7-10700, 11.7 GB memory. Its got a static IP and bridged to the local network which has a DNS server which I am confident is working because I can see the lookups and replies.

 

Wanting to get a lab running for NSX-T 3.0. Relatively new to this.

 

Thanks.


Windows 10 2004 with player 12 ?

$
0
0

My CPU incompatible with anything above version 12 of workstation player

The new Windows 10 2004 won't install unless I remove Player 12.

Will there be a way to run player 12 on windows 10 2004 once I upgrade ? will it really break something or Microsoft is just being too cautious by blocking version 12 ?

vRA8: Easiest way to get the project ID for use on custom form?

$
0
0

I need to get the project ID to use as an input to an action on a custom form. I am wondering if there is an easier way than calling the vRA API to list all projects and then parse the ID from the response. While I can certainly go this route I'm trying to be as efficient as possible as to not cause long form load times.

 

Thanks in advance!

Architecture Suggestion

$
0
0

Wondering if someone could bless this or suggest optional design.

 

I have three Servers connected via a pair of stacked Switches (dedicated to iSCSI and vMotion) to an iSCSI SAN.  Currently I am using the built in 1Gbps ports as follows:

 

vSwitch0

nic0 - LAN

 

vSwitch1

nic1 - iSCSI

nic2 - iSCSI

nic3 - iSCSI (vMotion enabled)

 

The iSCSI links are spread across the two switches so that if one goes down, connection to SAN will not be lost.  Each host has only about 5 VMs on it so in order to obtain some more density and not saturate the single LAN port I have obtained new Intel I350-T4 NICs that I will be installing this weekend.

 

New design will be (vCenter is on LAN)

 

vSwitch0

Broadcom nic0 - LAN LAG1

Broadcom nic1 - LAN LAG2

 

vSwitch1

Broadcom nic2 - iSCSI vMotion LAG1

Broadcom nic3 - iSCSI vMotion LAG2

 

vSwitch2

Intel nic0 - iSCSI

Intel nic1 - iSCSI

Intel nic2 - iSCSI

Intel nic3 - iSCSI

 

Not sure if I should configure VLANs on switches?  Or maybe run Fault Tolerance and vMotion as two different VLANs on vSwitch 1 over 2Gbps LAG?

 

I can conceive of the concepts but flipping all the right switches is the tough part.

 

Appreciate anyone's insight.

Install VmWare to anchient server

$
0
0

I have ancient server based to two XEON processor and X6DVA-4G motherboard. But it has 12 GB memory, big RAID controller, good cooling system and working stable and fine.

My main problem, it working only on Linux (or any version of Windows), but not work in any version of VmWare.

Usually I load any Linux to this server with option acpi=off and any Linux working fine, windows chose correct options automatically.

How is possible to install to this server VmWare? How to force VmWare working as Linux with mode acpi=off ?1

With Horizon for Linux (not enterprise) HCS and auth question

$
0
0

With Horizon for Linux (not enterprise) do you still setup HCS?

Also since there is no AD auth with non enterprise how do you auth to the desktop?